The decree of February 7, 1996 defines the evaluation method of
asbestos containing flockings.
The evaluation varies from 1 to 3 :
- 1 : periodic control of the state of conservation of the product,
- 2 : monitoring the level of dust contamination,
- 3 : removal.
The result is obtained by filling from left to right the columns of the following grid :
| Degradation and Surface quality | Physical protection | Circulations of air | Shocks and vibrations | Result | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bad condition or separation | 3 | |||||||||||
| low | 1 | |||||||||||
| low | middle | 1 | ||||||||||
| high | 2 | |||||||||||
| low | 1 | |||||||||||
| P | middle | middle | 1 | |||||||||
| high | 2 | |||||||||||
| low | 2 | |||||||||||
| high | middle | 2 | ||||||||||
| high | 2 | |||||||||||
| Coating or not with local degradations | ||||||||||||
| low | 2 | |||||||||||
| low | middle | 2 | ||||||||||
| high | 2 | |||||||||||
| low | 2 | |||||||||||
| NP | middle | middle | 2 | |||||||||
| high | 3 | |||||||||||
| low | 2 | |||||||||||
| high | middle | 3 | ||||||||||
| high | 3 | |||||||||||
| low | 1 | |||||||||||
| low | middle | 1 | ||||||||||
| high | 2 | |||||||||||
| low | 1 | |||||||||||
| P | middle | middle | 1 | |||||||||
| high | 2 | |||||||||||
| low | 2 | |||||||||||
| high | middle | 2 | ||||||||||
| high | 2 | |||||||||||
| Not coated nonimpregnated in good condition | ||||||||||||
| low | 1 | |||||||||||
| low | middle | 2 | ||||||||||
| high | 2 | |||||||||||
| low | 1 | |||||||||||
| NP | middle | middle | 2 | |||||||||
| high | 2 | |||||||||||
| low | 2 | |||||||||||
| high | middle | 3 | ||||||||||
| high | 3 | |||||||||||
| Impregnation in heart in good condition or coating of surface in good condition | 1 | |||||||||||